| 1 | <?xml version="1.0" encoding="UTF-8"?> |
| 2 | <export version="D"> |
| 3 | <design> |
| 4 | <source>C:\Users\kremlin\kicad\projects\bbb-bort\bbb-bort.sch</source> |
| 5 | <date>12/28/2018 11:39:30 AM</date> |
| 6 | <tool>Eeschema (5.0.1)-3</tool> |
| 7 | <sheet number="1" name="/" tstamps="/"> |
| 8 | <title_block> |
| 9 | <title>bort's brain</title> |
| 10 | <company>kremlinware unlimited</company> |
| 11 | <rev>A1</rev> |
| 12 | <date>2018-12-28</date> |
| 13 | <source>bbb-bort.sch</source> |
| 14 | <comment number="1" value="i'm the one who press that button"/> |
| 15 | <comment number="2" value="sweaty palms get caught bluffin"/> |
| 16 | <comment number="3" value="fold a man into nothin, for nothin"/> |
| 17 | <comment number="4" value=""/> |
| 18 | </title_block> |
| 19 | </sheet> |
| 20 | </design> |
| 21 | <components> |
| 22 | <comp ref="P8"> |
| 23 | <value>BeagleBone_Black_Header</value> |
| 24 | <footprint>Socket_BeagleBone_Black:Socket_BeagleBone_Black</footprint> |
| 25 | <fields> |
| 26 | <field name="manf#">67996-150HLF</field> |
| 27 | </fields> |
| 28 | <libsource lib="Connector_Generic" part="Conn_02x23_Odd_Even" description="Generic connector, double row, 02x23, odd/even pin numbering scheme (row 1 odd numbers, row 2 even numbers), script generated (kicad-library-utils/schlib/autogen/connector/)"/> |
| 29 | <sheetpath names="/" tstamps="/"/> |
| 30 | <tstamp>55DF7DE1</tstamp> |
| 31 | </comp> |
| 32 | <comp ref="U3"> |
| 33 | <value>74166</value> |
| 34 | <footprint>kicad-library:NEW-DIP254P762X508-16</footprint> |
| 35 | <fields> |
| 36 | <field name="manf#">SN74HC166N</field> |
| 37 | </fields> |
| 38 | <libsource lib="74xx_IEEE" part="74166" description=""/> |
| 39 | <sheetpath names="/" tstamps="/"/> |
| 40 | <tstamp>5C2DCFC3</tstamp> |
| 41 | </comp> |
| 42 | <comp ref="U1"> |
| 43 | <value>4504</value> |
| 44 | <footprint>kicad-library:NEW-DIP254P762X508-16</footprint> |
| 45 | <datasheet>http://www.ti.com/lit/ds/symlink/cd4504b.pdf</datasheet> |
| 46 | <fields> |
| 47 | <field name="manf#"> CD4504BEG4</field> |
| 48 | </fields> |
| 49 | <libsource lib="4xxx" part="4504" description="CMOS Hex Voltage-Level Shifter for TTL-to-CMOS or CMOS-to-CMOS, DIP-16/SOIC-16/TSSOP-16"/> |
| 50 | <sheetpath names="/" tstamps="/"/> |
| 51 | <tstamp>5C2E1ABC</tstamp> |
| 52 | </comp> |
| 53 | <comp ref="U2"> |
| 54 | <value>4504</value> |
| 55 | <footprint>kicad-library:NEW-DIP254P762X508-16</footprint> |
| 56 | <datasheet>http://www.ti.com/lit/ds/symlink/cd4504b.pdf</datasheet> |
| 57 | <fields> |
| 58 | <field name="manf#"> CD4504BEG4</field> |
| 59 | </fields> |
| 60 | <libsource lib="4xxx" part="4504" description="CMOS Hex Voltage-Level Shifter for TTL-to-CMOS or CMOS-to-CMOS, DIP-16/SOIC-16/TSSOP-16"/> |
| 61 | <sheetpath names="/" tstamps="/"/> |
| 62 | <tstamp>5C2E1BA8</tstamp> |
| 63 | </comp> |
| 64 | <comp ref="U7"> |
| 65 | <value>74166</value> |
| 66 | <footprint>kicad-library:NEW-DIP254P762X508-16</footprint> |
| 67 | <fields> |
| 68 | <field name="manf#">SN74HC166N</field> |
| 69 | </fields> |
| 70 | <libsource lib="74xx_IEEE" part="74166" description=""/> |
| 71 | <sheetpath names="/" tstamps="/"/> |
| 72 | <tstamp>5C339CD5</tstamp> |
| 73 | </comp> |
| 74 | <comp ref="U6"> |
| 75 | <value>74166</value> |
| 76 | <footprint>kicad-library:NEW-DIP254P762X508-16</footprint> |
| 77 | <fields> |
| 78 | <field name="manf#">SN74HC166N</field> |
| 79 | </fields> |
| 80 | <libsource lib="74xx_IEEE" part="74166" description=""/> |
| 81 | <sheetpath names="/" tstamps="/"/> |
| 82 | <tstamp>5C345D5D</tstamp> |
| 83 | </comp> |
| 84 | <comp ref="U5"> |
| 85 | <value>74166</value> |
| 86 | <footprint>kicad-library:NEW-DIP254P762X508-16</footprint> |
| 87 | <fields> |
| 88 | <field name="manf#">SN74HC166N</field> |
| 89 | </fields> |
| 90 | <libsource lib="74xx_IEEE" part="74166" description=""/> |
| 91 | <sheetpath names="/" tstamps="/"/> |
| 92 | <tstamp>5C346672</tstamp> |
| 93 | </comp> |
| 94 | <comp ref="U4"> |
| 95 | <value>74166</value> |
| 96 | <footprint>kicad-library:NEW-DIP254P762X508-16</footprint> |
| 97 | <fields> |
| 98 | <field name="manf#">SN74HC166N</field> |
| 99 | </fields> |
| 100 | <libsource lib="74xx_IEEE" part="74166" description=""/> |
| 101 | <sheetpath names="/" tstamps="/"/> |
| 102 | <tstamp>5C347042</tstamp> |
| 103 | </comp> |
| 104 | <comp ref="J1"> |
| 105 | <value>640456-8</value> |
| 106 | <footprint>.pretty:NEW-640456-8</footprint> |
| 107 | <fields> |
| 108 | <field name="manf#"> 640456-8</field> |
| 109 | </fields> |
| 110 | <libsource lib="symbols" part="640456-8" description=""/> |
| 111 | <sheetpath names="/" tstamps="/"/> |
| 112 | <tstamp>5C29A912</tstamp> |
| 113 | </comp> |
| 114 | <comp ref="J2"> |
| 115 | <value>640456-8</value> |
| 116 | <footprint>.pretty:NEW-640456-8</footprint> |
| 117 | <fields> |
| 118 | <field name="manf#"> 640456-8</field> |
| 119 | </fields> |
| 120 | <libsource lib="symbols" part="640456-8" description=""/> |
| 121 | <sheetpath names="/" tstamps="/"/> |
| 122 | <tstamp>5C29AA60</tstamp> |
| 123 | </comp> |
| 124 | <comp ref="J3"> |
| 125 | <value>640456-8</value> |
| 126 | <footprint>.pretty:NEW-640456-8</footprint> |
| 127 | <fields> |
| 128 | <field name="manf#"> 640456-8</field> |
| 129 | </fields> |
| 130 | <libsource lib="symbols" part="640456-8" description=""/> |
| 131 | <sheetpath names="/" tstamps="/"/> |
| 132 | <tstamp>5C29ACD3</tstamp> |
| 133 | </comp> |
| 134 | <comp ref="J4"> |
| 135 | <value>640456-8</value> |
| 136 | <footprint>.pretty:NEW-640456-8</footprint> |
| 137 | <fields> |
| 138 | <field name="manf#"> 640456-8</field> |
| 139 | </fields> |
| 140 | <libsource lib="symbols" part="640456-8" description=""/> |
| 141 | <sheetpath names="/" tstamps="/"/> |
| 142 | <tstamp>5C29AD70</tstamp> |
| 143 | </comp> |
| 144 | <comp ref="J5"> |
| 145 | <value>640456-8</value> |
| 146 | <footprint>.pretty:NEW-640456-8</footprint> |
| 147 | <fields> |
| 148 | <field name="manf#"> 640456-8</field> |
| 149 | </fields> |
| 150 | <libsource lib="symbols" part="640456-8" description=""/> |
| 151 | <sheetpath names="/" tstamps="/"/> |
| 152 | <tstamp>5C29AE73</tstamp> |
| 153 | </comp> |
| 154 | <comp ref="J6"> |
| 155 | <value>640456-8</value> |
| 156 | <footprint>.pretty:NEW-640456-8</footprint> |
| 157 | <fields> |
| 158 | <field name="manf#"> 640456-8</field> |
| 159 | </fields> |
| 160 | <libsource lib="symbols" part="640456-8" description=""/> |
| 161 | <sheetpath names="/" tstamps="/"/> |
| 162 | <tstamp>5C29AF80</tstamp> |
| 163 | </comp> |
| 164 | <comp ref="RN2"> |
| 165 | <value>4609X-101-103LF</value> |
| 166 | <footprint>digikey-footprints:USE-SIP-9_P2.54mm</footprint> |
| 167 | <datasheet>https://www.bourns.com/docs/Product-Datasheets/4600x.pdf</datasheet> |
| 168 | <fields> |
| 169 | <field name="Category">Resistors</field> |
| 170 | <field name="DK_Datasheet_Link">https://www.bourns.com/docs/Product-Datasheets/4600x.pdf</field> |
| 171 | <field name="DK_Detail_Page">/product-detail/en/bourns-inc/4609X-101-103LF/4609X-101-103LF-ND/2634616</field> |
| 172 | <field name="Description">RES ARRAY 8 RES 10K OHM 9SIP</field> |
| 173 | <field name="Digi-Key_PN">4609X-101-103LF-ND</field> |
| 174 | <field name="Family">Resistor Networks, Arrays</field> |
| 175 | <field name="MPN">4609X-101-103LF</field> |
| 176 | <field name="Manufacturer">Bourns Inc.</field> |
| 177 | <field name="Status">Active</field> |
| 178 | <field name="manf#">4609X-101-103LF</field> |
| 179 | </fields> |
| 180 | <libsource lib="dk_Resistor-Networks-Arrays" part="4609X-101-103LF" description="RES ARRAY 8 RES 10K OHM 9SIP"/> |
| 181 | <sheetpath names="/" tstamps="/"/> |
| 182 | <tstamp>5C2907A3</tstamp> |
| 183 | </comp> |
| 184 | <comp ref="RN4"> |
| 185 | <value>4609X-101-103LF</value> |
| 186 | <footprint>digikey-footprints:USE-SIP-9_P2.54mm</footprint> |
| 187 | <datasheet>https://www.bourns.com/docs/Product-Datasheets/4600x.pdf</datasheet> |
| 188 | <fields> |
| 189 | <field name="Category">Resistors</field> |
| 190 | <field name="DK_Datasheet_Link">https://www.bourns.com/docs/Product-Datasheets/4600x.pdf</field> |
| 191 | <field name="DK_Detail_Page">/product-detail/en/bourns-inc/4609X-101-103LF/4609X-101-103LF-ND/2634616</field> |
| 192 | <field name="Description">RES ARRAY 8 RES 10K OHM 9SIP</field> |
| 193 | <field name="Digi-Key_PN">4609X-101-103LF-ND</field> |
| 194 | <field name="Family">Resistor Networks, Arrays</field> |
| 195 | <field name="MPN">4609X-101-103LF</field> |
| 196 | <field name="Manufacturer">Bourns Inc.</field> |
| 197 | <field name="Status">Active</field> |
| 198 | <field name="manf#">4609X-101-103LF</field> |
| 199 | </fields> |
| 200 | <libsource lib="dk_Resistor-Networks-Arrays" part="4609X-101-103LF" description="RES ARRAY 8 RES 10K OHM 9SIP"/> |
| 201 | <sheetpath names="/" tstamps="/"/> |
| 202 | <tstamp>5C3CDCE8</tstamp> |
| 203 | </comp> |
| 204 | <comp ref="RN6"> |
| 205 | <value>4609X-101-103LF</value> |
| 206 | <footprint>digikey-footprints:USE-SIP-9_P2.54mm</footprint> |
| 207 | <datasheet>https://www.bourns.com/docs/Product-Datasheets/4600x.pdf</datasheet> |
| 208 | <fields> |
| 209 | <field name="Category">Resistors</field> |
| 210 | <field name="DK_Datasheet_Link">https://www.bourns.com/docs/Product-Datasheets/4600x.pdf</field> |
| 211 | <field name="DK_Detail_Page">/product-detail/en/bourns-inc/4609X-101-103LF/4609X-101-103LF-ND/2634616</field> |
| 212 | <field name="Description">RES ARRAY 8 RES 10K OHM 9SIP</field> |
| 213 | <field name="Digi-Key_PN">4609X-101-103LF-ND</field> |
| 214 | <field name="Family">Resistor Networks, Arrays</field> |
| 215 | <field name="MPN">4609X-101-103LF</field> |
| 216 | <field name="Manufacturer">Bourns Inc.</field> |
| 217 | <field name="Status">Active</field> |
| 218 | <field name="manf#">4609X-101-103LF</field> |
| 219 | </fields> |
| 220 | <libsource lib="dk_Resistor-Networks-Arrays" part="4609X-101-103LF" description="RES ARRAY 8 RES 10K OHM 9SIP"/> |
| 221 | <sheetpath names="/" tstamps="/"/> |
| 222 | <tstamp>5C3CDDAC</tstamp> |
| 223 | </comp> |
| 224 | <comp ref="RN5"> |
| 225 | <value>4609X-101-103LF</value> |
| 226 | <footprint>digikey-footprints:USE-SIP-9_P2.54mm</footprint> |
| 227 | <datasheet>https://www.bourns.com/docs/Product-Datasheets/4600x.pdf</datasheet> |
| 228 | <fields> |
| 229 | <field name="Category">Resistors</field> |
| 230 | <field name="DK_Datasheet_Link">https://www.bourns.com/docs/Product-Datasheets/4600x.pdf</field> |
| 231 | <field name="DK_Detail_Page">/product-detail/en/bourns-inc/4609X-101-103LF/4609X-101-103LF-ND/2634616</field> |
| 232 | <field name="Description">RES ARRAY 8 RES 10K OHM 9SIP</field> |
| 233 | <field name="Digi-Key_PN">4609X-101-103LF-ND</field> |
| 234 | <field name="Family">Resistor Networks, Arrays</field> |
| 235 | <field name="MPN">4609X-101-103LF</field> |
| 236 | <field name="Manufacturer">Bourns Inc.</field> |
| 237 | <field name="Status">Active</field> |
| 238 | <field name="manf#">4609X-101-103LF</field> |
| 239 | </fields> |
| 240 | <libsource lib="dk_Resistor-Networks-Arrays" part="4609X-101-103LF" description="RES ARRAY 8 RES 10K OHM 9SIP"/> |
| 241 | <sheetpath names="/" tstamps="/"/> |
| 242 | <tstamp>5C3CDE16</tstamp> |
| 243 | </comp> |
| 244 | <comp ref="RN3"> |
| 245 | <value>4609X-101-103LF</value> |
| 246 | <footprint>digikey-footprints:USE-SIP-9_P2.54mm</footprint> |
| 247 | <datasheet>https://www.bourns.com/docs/Product-Datasheets/4600x.pdf</datasheet> |
| 248 | <fields> |
| 249 | <field name="Category">Resistors</field> |
| 250 | <field name="DK_Datasheet_Link">https://www.bourns.com/docs/Product-Datasheets/4600x.pdf</field> |
| 251 | <field name="DK_Detail_Page">/product-detail/en/bourns-inc/4609X-101-103LF/4609X-101-103LF-ND/2634616</field> |
| 252 | <field name="Description">RES ARRAY 8 RES 10K OHM 9SIP</field> |
| 253 | <field name="Digi-Key_PN">4609X-101-103LF-ND</field> |
| 254 | <field name="Family">Resistor Networks, Arrays</field> |
| 255 | <field name="MPN">4609X-101-103LF</field> |
| 256 | <field name="Manufacturer">Bourns Inc.</field> |
| 257 | <field name="Status">Active</field> |
| 258 | <field name="manf#">4609X-101-103LF</field> |
| 259 | </fields> |
| 260 | <libsource lib="dk_Resistor-Networks-Arrays" part="4609X-101-103LF" description="RES ARRAY 8 RES 10K OHM 9SIP"/> |
| 261 | <sheetpath names="/" tstamps="/"/> |
| 262 | <tstamp>5C3CDF3A</tstamp> |
| 263 | </comp> |
| 264 | <comp ref="RN1"> |
| 265 | <value>4609X-101-103LF</value> |
| 266 | <footprint>digikey-footprints:USE-SIP-9_P2.54mm</footprint> |
| 267 | <datasheet>https://www.bourns.com/docs/Product-Datasheets/4600x.pdf</datasheet> |
| 268 | <fields> |
| 269 | <field name="Category">Resistors</field> |
| 270 | <field name="DK_Datasheet_Link">https://www.bourns.com/docs/Product-Datasheets/4600x.pdf</field> |
| 271 | <field name="DK_Detail_Page">/product-detail/en/bourns-inc/4609X-101-103LF/4609X-101-103LF-ND/2634616</field> |
| 272 | <field name="Description">RES ARRAY 8 RES 10K OHM 9SIP</field> |
| 273 | <field name="Digi-Key_PN">4609X-101-103LF-ND</field> |
| 274 | <field name="Family">Resistor Networks, Arrays</field> |
| 275 | <field name="MPN">4609X-101-103LF</field> |
| 276 | <field name="Manufacturer">Bourns Inc.</field> |
| 277 | <field name="Status">Active</field> |
| 278 | <field name="manf#">4609X-101-103LF</field> |
| 279 | </fields> |
| 280 | <libsource lib="dk_Resistor-Networks-Arrays" part="4609X-101-103LF" description="RES ARRAY 8 RES 10K OHM 9SIP"/> |
| 281 | <sheetpath names="/" tstamps="/"/> |
| 282 | <tstamp>5C3CDFB6</tstamp> |
| 283 | </comp> |
| 284 | <comp ref="P9"> |
| 285 | <value>BeagleBone_Black_Header</value> |
| 286 | <footprint>Socket_BeagleBone_Black:Socket_BeagleBone_Black</footprint> |
| 287 | <fields> |
| 288 | <field name="manf#">67996-150HLF</field> |
| 289 | </fields> |
| 290 | <libsource lib="Connector_Generic" part="Conn_02x23_Odd_Even" description="Generic connector, double row, 02x23, odd/even pin numbering scheme (row 1 odd numbers, row 2 even numbers), script generated (kicad-library-utils/schlib/autogen/connector/)"/> |
| 291 | <sheetpath names="/" tstamps="/"/> |
| 292 | <tstamp>55DF7DBA</tstamp> |
| 293 | </comp> |
| 294 | <comp ref="U8"> |
| 295 | <value>74166</value> |
| 296 | <footprint>kicad-library:NEW-DIP254P762X508-16</footprint> |
| 297 | <fields> |
| 298 | <field name="manf#">SN74HC166N</field> |
| 299 | </fields> |
| 300 | <libsource lib="74xx_IEEE" part="74166" description=""/> |
| 301 | <sheetpath names="/" tstamps="/"/> |
| 302 | <tstamp>5C343F96</tstamp> |
| 303 | </comp> |
| 304 | <comp ref="H4"> |
| 305 | <value>MountingHole</value> |
| 306 | <footprint>MountingHole:MountingHole_2.2mm_M2</footprint> |
| 307 | <datasheet>~</datasheet> |
| 308 | <libsource lib="Mechanical" part="MountingHole" description="Mounting Hole without connection"/> |
| 309 | <sheetpath names="/" tstamps="/"/> |
| 310 | <tstamp>5C81EB00</tstamp> |
| 311 | </comp> |
| 312 | <comp ref="H2"> |
| 313 | <value>MountingHole</value> |
| 314 | <footprint>MountingHole:MountingHole_2.2mm_M2</footprint> |
| 315 | <datasheet>~</datasheet> |
| 316 | <libsource lib="Mechanical" part="MountingHole" description="Mounting Hole without connection"/> |
| 317 | <sheetpath names="/" tstamps="/"/> |
| 318 | <tstamp>5C81F04C</tstamp> |
| 319 | </comp> |
| 320 | <comp ref="H3"> |
| 321 | <value>MountingHole</value> |
| 322 | <footprint>MountingHole:MountingHole_2.2mm_M2</footprint> |
| 323 | <datasheet>~</datasheet> |
| 324 | <libsource lib="Mechanical" part="MountingHole" description="Mounting Hole without connection"/> |
| 325 | <sheetpath names="/" tstamps="/"/> |
| 326 | <tstamp>5C827EBA</tstamp> |
| 327 | </comp> |
| 328 | <comp ref="H1"> |
| 329 | <value>MountingHole</value> |
| 330 | <footprint>MountingHole:MountingHole_2.2mm_M2</footprint> |
| 331 | <datasheet>~</datasheet> |
| 332 | <libsource lib="Mechanical" part="MountingHole" description="Mounting Hole without connection"/> |
| 333 | <sheetpath names="/" tstamps="/"/> |
| 334 | <tstamp>5C827EC1</tstamp> |
| 335 | </comp> |
| 336 | </components> |
| 337 | <libparts> |
| 338 | <libpart lib="4xxx" part="4504"> |
| 339 | <description>CMOS Hex Voltage-Level Shifter for TTL-to-CMOS or CMOS-to-CMOS, DIP-16/SOIC-16/TSSOP-16</description> |
| 340 | <docs>http://www.ti.com/lit/ds/symlink/cd4504b.pdf</docs> |
| 341 | <footprints> |
| 342 | <fp>DIP*W7.62mm*</fp> |
| 343 | <fp>SOIC*3.9x9.9mm*P1.27mm*</fp> |
| 344 | <fp>TSSOP*4.4x5mm*P0.65mm*</fp> |
| 345 | </footprints> |
| 346 | <fields> |
| 347 | <field name="Reference">U</field> |
| 348 | <field name="Value">4504</field> |
| 349 | </fields> |
| 350 | <pins> |
| 351 | <pin num="1" name="VCC" type="power_in"/> |
| 352 | <pin num="2" name="Aout" type="output"/> |
| 353 | <pin num="3" name="Ain" type="input"/> |
| 354 | <pin num="4" name="Bout" type="output"/> |
| 355 | <pin num="5" name="Bin" type="input"/> |
| 356 | <pin num="6" name="Cout" type="output"/> |
| 357 | <pin num="7" name="Cin" type="input"/> |
| 358 | <pin num="8" name="VSS" type="power_in"/> |
| 359 | <pin num="9" name="Din" type="input"/> |
| 360 | <pin num="10" name="Dout" type="output"/> |
| 361 | <pin num="11" name="Ein" type="input"/> |
| 362 | <pin num="12" name="Eout" type="output"/> |
| 363 | <pin num="13" name="Select" type="input"/> |
| 364 | <pin num="14" name="Fin" type="input"/> |
| 365 | <pin num="15" name="Fout" type="output"/> |
| 366 | <pin num="16" name="VDD" type="power_in"/> |
| 367 | </pins> |
| 368 | </libpart> |
| 369 | <libpart lib="74xx_IEEE" part="74166"> |
| 370 | <fields> |
| 371 | <field name="Reference">U</field> |
| 372 | <field name="Value">74166</field> |
| 373 | </fields> |
| 374 | <pins> |
| 375 | <pin num="1" name="SER" type="input"/> |
| 376 | <pin num="2" name="A" type="input"/> |
| 377 | <pin num="3" name="B" type="input"/> |
| 378 | <pin num="4" name="C" type="input"/> |
| 379 | <pin num="5" name="D" type="input"/> |
| 380 | <pin num="6" name="CLKINH" type="input"/> |
| 381 | <pin num="7" name="CLK" type="input"/> |
| 382 | <pin num="8" name="GND" type="power_in"/> |
| 383 | <pin num="9" name="~CLR" type="input"/> |
| 384 | <pin num="10" name="E" type="input"/> |
| 385 | <pin num="11" name="F" type="input"/> |
| 386 | <pin num="12" name="G" type="input"/> |
| 387 | <pin num="13" name="QH" type="3state"/> |
| 388 | <pin num="14" name="H" type="input"/> |
| 389 | <pin num="15" name="SHLD" type="input"/> |
| 390 | <pin num="16" name="VCC" type="power_in"/> |
| 391 | </pins> |
| 392 | </libpart> |
| 393 | <libpart lib="Connector_Generic" part="Conn_02x23_Odd_Even"> |
| 394 | <description>Generic connector, double row, 02x23, odd/even pin numbering scheme (row 1 odd numbers, row 2 even numbers), script generated (kicad-library-utils/schlib/autogen/connector/)</description> |
| 395 | <docs>~</docs> |
| 396 | <footprints> |
| 397 | <fp>Connector*:*_2x??_*</fp> |
| 398 | </footprints> |
| 399 | <fields> |
| 400 | <field name="Reference">J</field> |
| 401 | <field name="Value">Conn_02x23_Odd_Even</field> |
| 402 | </fields> |
| 403 | <pins> |
| 404 | <pin num="1" name="Pin_1" type="passive"/> |
| 405 | <pin num="2" name="Pin_2" type="passive"/> |
| 406 | <pin num="3" name="Pin_3" type="passive"/> |
| 407 | <pin num="4" name="Pin_4" type="passive"/> |
| 408 | <pin num="5" name="Pin_5" type="passive"/> |
| 409 | <pin num="6" name="Pin_6" type="passive"/> |
| 410 | <pin num="7" name="Pin_7" type="passive"/> |
| 411 | <pin num="8" name="Pin_8" type="passive"/> |
| 412 | <pin num="9" name="Pin_9" type="passive"/> |
| 413 | <pin num="10" name="Pin_10" type="passive"/> |
| 414 | <pin num="11" name="Pin_11" type="passive"/> |
| 415 | <pin num="12" name="Pin_12" type="passive"/> |
| 416 | <pin num="13" name="Pin_13" type="passive"/> |
| 417 | <pin num="14" name="Pin_14" type="passive"/> |
| 418 | <pin num="15" name="Pin_15" type="passive"/> |
| 419 | <pin num="16" name="Pin_16" type="passive"/> |
| 420 | <pin num="17" name="Pin_17" type="passive"/> |
| 421 | <pin num="18" name="Pin_18" type="passive"/> |
| 422 | <pin num="19" name="Pin_19" type="passive"/> |
| 423 | <pin num="20" name="Pin_20" type="passive"/> |
| 424 | <pin num="21" name="Pin_21" type="passive"/> |
| 425 | <pin num="22" name="Pin_22" type="passive"/> |
| 426 | <pin num="23" name="Pin_23" type="passive"/> |
| 427 | <pin num="24" name="Pin_24" type="passive"/> |
| 428 | <pin num="25" name="Pin_25" type="passive"/> |
| 429 | <pin num="26" name="Pin_26" type="passive"/> |
| 430 | <pin num="27" name="Pin_27" type="passive"/> |
| 431 | <pin num="28" name="Pin_28" type="passive"/> |
| 432 | <pin num="29" name="Pin_29" type="passive"/> |
| 433 | <pin num="30" name="Pin_30" type="passive"/> |
| 434 | <pin num="31" name="Pin_31" type="passive"/> |
| 435 | <pin num="32" name="Pin_32" type="passive"/> |
| 436 | <pin num="33" name="Pin_33" type="passive"/> |
| 437 | <pin num="34" name="Pin_34" type="passive"/> |
| 438 | <pin num="35" name="Pin_35" type="passive"/> |
| 439 | <pin num="36" name="Pin_36" type="passive"/> |
| 440 | <pin num="37" name="Pin_37" type="passive"/> |
| 441 | <pin num="38" name="Pin_38" type="passive"/> |
| 442 | <pin num="39" name="Pin_39" type="passive"/> |
| 443 | <pin num="40" name="Pin_40" type="passive"/> |
| 444 | <pin num="41" name="Pin_41" type="passive"/> |
| 445 | <pin num="42" name="Pin_42" type="passive"/> |
| 446 | <pin num="43" name="Pin_43" type="passive"/> |
| 447 | <pin num="44" name="Pin_44" type="passive"/> |
| 448 | <pin num="45" name="Pin_45" type="passive"/> |
| 449 | <pin num="46" name="Pin_46" type="passive"/> |
| 450 | </pins> |
| 451 | </libpart> |
| 452 | <libpart lib="Mechanical" part="MountingHole"> |
| 453 | <description>Mounting Hole without connection</description> |
| 454 | <docs>~</docs> |
| 455 | <footprints> |
| 456 | <fp>MountingHole*</fp> |
| 457 | </footprints> |
| 458 | <fields> |
| 459 | <field name="Reference">H</field> |
| 460 | <field name="Value">MountingHole</field> |
| 461 | </fields> |
| 462 | </libpart> |
| 463 | <libpart lib="dk_Resistor-Networks-Arrays" part="4609X-101-103LF"> |
| 464 | <description>RES ARRAY 8 RES 10K OHM 9SIP</description> |
| 465 | <docs>https://www.bourns.com/docs/Product-Datasheets/4600x.pdf</docs> |
| 466 | <fields> |
| 467 | <field name="Reference">RN</field> |
| 468 | <field name="Value">4609X-101-103LF</field> |
| 469 | <field name="Footprint">digikey-footprints:SIP-9_P2.54mm</field> |
| 470 | <field name="Datasheet">https://www.bourns.com/docs/Product-Datasheets/4600x.pdf</field> |
| 471 | <field name="Digi-Key_PN">4609X-101-103LF-ND</field> |
| 472 | <field name="MPN">4609X-101-103LF</field> |
| 473 | <field name="Category">Resistors</field> |
| 474 | <field name="Family">Resistor Networks, Arrays</field> |
| 475 | <field name="DK_Datasheet_Link">https://www.bourns.com/docs/Product-Datasheets/4600x.pdf</field> |
| 476 | <field name="DK_Detail_Page">/product-detail/en/bourns-inc/4609X-101-103LF/4609X-101-103LF-ND/2634616</field> |
| 477 | <field name="Description">RES ARRAY 8 RES 10K OHM 9SIP</field> |
| 478 | <field name="Manufacturer">Bourns Inc.</field> |
| 479 | <field name="Status">Active</field> |
| 480 | </fields> |
| 481 | <pins> |
| 482 | <pin num="1" name="~" type="passive"/> |
| 483 | <pin num="2" name="~" type="passive"/> |
| 484 | <pin num="3" name="~" type="passive"/> |
| 485 | <pin num="4" name="~" type="passive"/> |
| 486 | <pin num="5" name="~" type="passive"/> |
| 487 | <pin num="6" name="~" type="passive"/> |
| 488 | <pin num="7" name="~" type="passive"/> |
| 489 | <pin num="8" name="~" type="passive"/> |
| 490 | <pin num="9" name="~" type="passive"/> |
| 491 | </pins> |
| 492 | </libpart> |
| 493 | <libpart lib="symbols" part="640456-8"> |
| 494 | <footprints> |
| 495 | <fp>CONN8_640456-8</fp> |
| 496 | </footprints> |
| 497 | <fields> |
| 498 | <field name="Reference">J</field> |
| 499 | <field name="Value">640456-8</field> |
| 500 | <field name="Footprint">CONN8_640456-8</field> |
| 501 | </fields> |
| 502 | <pins> |
| 503 | <pin num="1" name="1" type="unspc"/> |
| 504 | <pin num="2" name="2" type="unspc"/> |
| 505 | <pin num="3" name="3" type="unspc"/> |
| 506 | <pin num="4" name="4" type="unspc"/> |
| 507 | <pin num="5" name="5" type="unspc"/> |
| 508 | <pin num="6" name="6" type="unspc"/> |
| 509 | <pin num="7" name="7" type="unspc"/> |
| 510 | <pin num="8" name="8" type="unspc"/> |
| 511 | </pins> |
| 512 | </libpart> |
| 513 | </libparts> |
| 514 | <libraries> |
| 515 | <library logical="4xxx"> |
| 516 | <uri>C:\Program Files\KiCad\share\kicad\library/4xxx.lib</uri> |
| 517 | </library> |
| 518 | <library logical="74xx_IEEE"> |
| 519 | <uri>C:\Program Files\KiCad\share\kicad\library/74xx_IEEE.lib</uri> |
| 520 | </library> |
| 521 | <library logical="Connector_Generic"> |
| 522 | <uri>C:\Program Files\KiCad\share\kicad\library/Connector_Generic.lib</uri> |
| 523 | </library> |
| 524 | <library logical="Mechanical"> |
| 525 | <uri>C:\Program Files\KiCad\share\kicad\library/Mechanical.lib</uri> |
| 526 | </library> |
| 527 | <library logical="dk_Resistor-Networks-Arrays"> |
| 528 | <uri>C:/Users/kremlin/kicad/libraries/digikey-kicad-library/digikey-symbols/dk_Resistor-Networks-Arrays.lib</uri> |
| 529 | </library> |
| 530 | <library logical="symbols"> |
| 531 | <uri>C:/Users/kremlin/kicad/libraries/misc/KiCAD/symbols.lib</uri> |
| 532 | </library> |
| 533 | </libraries> |
| 534 | <nets> |
| 535 | <net code="1" name="GND"> |
| 536 | <node ref="U4" pin="1"/> |
| 537 | <node ref="U4" pin="8"/> |
| 538 | <node ref="U2" pin="13"/> |
| 539 | <node ref="U7" pin="1"/> |
| 540 | <node ref="U7" pin="8"/> |
| 541 | <node ref="U8" pin="1"/> |
| 542 | <node ref="U8" pin="8"/> |
| 543 | <node ref="RN1" pin="1"/> |
| 544 | <node ref="U1" pin="8"/> |
| 545 | <node ref="U1" pin="13"/> |
| 546 | <node ref="RN4" pin="1"/> |
| 547 | <node ref="RN6" pin="1"/> |
| 548 | <node ref="U5" pin="1"/> |
| 549 | <node ref="U5" pin="8"/> |
| 550 | <node ref="P9" pin="2"/> |
| 551 | <node ref="RN5" pin="1"/> |
| 552 | <node ref="U6" pin="1"/> |
| 553 | <node ref="U3" pin="1"/> |
| 554 | <node ref="U3" pin="8"/> |
| 555 | <node ref="RN3" pin="1"/> |
| 556 | <node ref="U2" pin="8"/> |
| 557 | <node ref="U6" pin="8"/> |
| 558 | <node ref="RN2" pin="1"/> |
| 559 | </net> |
| 560 | <net code="8" name="Net-(P9-Pad29)"> |
| 561 | <node ref="P9" pin="29"/> |
| 562 | </net> |
| 563 | <net code="9" name="Net-(P9-Pad15)"> |
| 564 | <node ref="P9" pin="15"/> |
| 565 | </net> |
| 566 | <net code="10" name="Net-(P9-Pad16)"> |
| 567 | <node ref="P9" pin="16"/> |
| 568 | </net> |
| 569 | <net code="11" name="Net-(P9-Pad17)"> |
| 570 | <node ref="P9" pin="17"/> |
| 571 | </net> |
| 572 | <net code="12" name="Net-(P9-Pad18)"> |
| 573 | <node ref="P9" pin="18"/> |
| 574 | </net> |
| 575 | <net code="13" name="Net-(P9-Pad19)"> |
| 576 | <node ref="P9" pin="19"/> |
| 577 | </net> |
| 578 | <net code="14" name="Net-(P9-Pad20)"> |
| 579 | <node ref="P9" pin="20"/> |
| 580 | </net> |
| 581 | <net code="15" name="Net-(P9-Pad21)"> |
| 582 | <node ref="P9" pin="21"/> |
| 583 | </net> |
| 584 | <net code="16" name="Net-(P9-Pad22)"> |
| 585 | <node ref="P9" pin="22"/> |
| 586 | </net> |
| 587 | <net code="17" name="Net-(P9-Pad23)"> |
| 588 | <node ref="P9" pin="23"/> |
| 589 | </net> |
| 590 | <net code="18" name="Net-(P9-Pad24)"> |
| 591 | <node ref="P9" pin="24"/> |
| 592 | </net> |
| 593 | <net code="19" name="Net-(P9-Pad25)"> |
| 594 | <node ref="P9" pin="25"/> |
| 595 | </net> |
| 596 | <net code="20" name="Net-(P9-Pad26)"> |
| 597 | <node ref="P9" pin="26"/> |
| 598 | </net> |
| 599 | <net code="21" name="Net-(P9-Pad27)"> |
| 600 | <node ref="P9" pin="27"/> |
| 601 | </net> |
| 602 | <net code="22" name="Net-(P9-Pad28)"> |
| 603 | <node ref="P9" pin="28"/> |
| 604 | </net> |
| 605 | <net code="23" name="Net-(P9-Pad14)"> |
| 606 | <node ref="P9" pin="14"/> |
| 607 | </net> |
| 608 | <net code="24" name="Net-(P9-Pad30)"> |
| 609 | <node ref="P9" pin="30"/> |
| 610 | </net> |
| 611 | <net code="25" name="Net-(P9-Pad31)"> |
| 612 | <node ref="P9" pin="31"/> |
| 613 | </net> |
| 614 | <net code="26" name="Net-(P9-Pad33)"> |
| 615 | <node ref="P9" pin="33"/> |
| 616 | </net> |
| 617 | <net code="27" name="Net-(P9-Pad35)"> |
| 618 | <node ref="P9" pin="35"/> |
| 619 | </net> |
| 620 | <net code="28" name="Net-(P9-Pad36)"> |
| 621 | <node ref="P9" pin="36"/> |
| 622 | </net> |
| 623 | <net code="29" name="Net-(P9-Pad37)"> |
| 624 | <node ref="P9" pin="37"/> |
| 625 | </net> |
| 626 | <net code="30" name="Net-(P9-Pad38)"> |
| 627 | <node ref="P9" pin="38"/> |
| 628 | </net> |
| 629 | <net code="31" name="Net-(P9-Pad39)"> |
| 630 | <node ref="P9" pin="39"/> |
| 631 | </net> |
| 632 | <net code="32" name="Net-(P9-Pad40)"> |
| 633 | <node ref="P9" pin="40"/> |
| 634 | </net> |
| 635 | <net code="33" name="Net-(P9-Pad41)"> |
| 636 | <node ref="P9" pin="41"/> |
| 637 | </net> |
| 638 | <net code="34" name="Net-(P9-Pad42)"> |
| 639 | <node ref="P9" pin="42"/> |
| 640 | </net> |
| 641 | <net code="35" name="Net-(P9-Pad1)"> |
| 642 | <node ref="P9" pin="1"/> |
| 643 | </net> |
| 644 | <net code="36" name="Net-(P9-Pad11)"> |
| 645 | <node ref="P9" pin="11"/> |
| 646 | </net> |
| 647 | <net code="37" name="Net-(P9-Pad12)"> |
| 648 | <node ref="P9" pin="12"/> |
| 649 | </net> |
| 650 | <net code="38" name="Net-(P9-Pad13)"> |
| 651 | <node ref="P9" pin="13"/> |
| 652 | </net> |
| 653 | <net code="39" name="GNDD"> |
| 654 | <node ref="P9" pin="43"/> |
| 655 | <node ref="P9" pin="46"/> |
| 656 | <node ref="P9" pin="45"/> |
| 657 | <node ref="P9" pin="44"/> |
| 658 | </net> |
| 659 | <net code="40" name="5v"> |
| 660 | <node ref="U3" pin="16"/> |
| 661 | <node ref="U2" pin="16"/> |
| 662 | <node ref="U1" pin="1"/> |
| 663 | <node ref="U6" pin="16"/> |
| 664 | <node ref="P9" pin="5"/> |
| 665 | <node ref="U4" pin="16"/> |
| 666 | <node ref="U8" pin="16"/> |
| 667 | <node ref="P9" pin="8"/> |
| 668 | <node ref="P9" pin="7"/> |
| 669 | <node ref="P9" pin="6"/> |
| 670 | <node ref="U5" pin="16"/> |
| 671 | <node ref="U7" pin="16"/> |
| 672 | </net> |
| 673 | <net code="41" name="PWR_BUT"> |
| 674 | <node ref="P9" pin="9"/> |
| 675 | </net> |
| 676 | <net code="42" name="SR3_QH"> |
| 677 | <node ref="U8" pin="13"/> |
| 678 | <node ref="U1" pin="7"/> |
| 679 | </net> |
| 680 | <net code="43" name="a5r"> |
| 681 | <node ref="J1" pin="4"/> |
| 682 | <node ref="U4" pin="5"/> |
| 683 | <node ref="RN1" pin="6"/> |
| 684 | </net> |
| 685 | <net code="44" name="a1r"> |
| 686 | <node ref="J1" pin="8"/> |
| 687 | <node ref="RN1" pin="2"/> |
| 688 | <node ref="U4" pin="14"/> |
| 689 | </net> |
| 690 | <net code="45" name="a2r"> |
| 691 | <node ref="RN1" pin="3"/> |
| 692 | <node ref="J1" pin="7"/> |
| 693 | <node ref="U4" pin="12"/> |
| 694 | </net> |
| 695 | <net code="46" name="a3r"> |
| 696 | <node ref="RN1" pin="4"/> |
| 697 | <node ref="U4" pin="11"/> |
| 698 | <node ref="J1" pin="6"/> |
| 699 | </net> |
| 700 | <net code="47" name="a4r"> |
| 701 | <node ref="J1" pin="5"/> |
| 702 | <node ref="RN1" pin="5"/> |
| 703 | <node ref="U4" pin="10"/> |
| 704 | </net> |
| 705 | <net code="48" name="a6r"> |
| 706 | <node ref="RN1" pin="7"/> |
| 707 | <node ref="U4" pin="4"/> |
| 708 | <node ref="J1" pin="3"/> |
| 709 | </net> |
| 710 | <net code="49" name="a7r"> |
| 711 | <node ref="J1" pin="2"/> |
| 712 | <node ref="U4" pin="3"/> |
| 713 | <node ref="RN1" pin="8"/> |
| 714 | </net> |
| 715 | <net code="50" name="a8r"> |
| 716 | <node ref="J1" pin="1"/> |
| 717 | <node ref="RN1" pin="9"/> |
| 718 | <node ref="U4" pin="2"/> |
| 719 | </net> |
| 720 | <net code="53" name="SR1_QH_T"> |
| 721 | <node ref="P8" pin="4"/> |
| 722 | <node ref="U1" pin="2"/> |
| 723 | </net> |
| 724 | <net code="54" name="SR2_QH"> |
| 725 | <node ref="U1" pin="5"/> |
| 726 | <node ref="U7" pin="13"/> |
| 727 | </net> |
| 728 | <net code="55" name="SR6_QH_T"> |
| 729 | <node ref="U1" pin="15"/> |
| 730 | <node ref="P8" pin="18"/> |
| 731 | </net> |
| 732 | <net code="56" name="SR1_QH"> |
| 733 | <node ref="U1" pin="3"/> |
| 734 | <node ref="U3" pin="13"/> |
| 735 | </net> |
| 736 | <net code="57" name="BB3.3"> |
| 737 | <node ref="U2" pin="1"/> |
| 738 | <node ref="U1" pin="16"/> |
| 739 | </net> |
| 740 | <net code="58" name="SR1_CLR_T"> |
| 741 | <node ref="U4" pin="9"/> |
| 742 | <node ref="U5" pin="9"/> |
| 743 | <node ref="U7" pin="9"/> |
| 744 | <node ref="U6" pin="9"/> |
| 745 | <node ref="U3" pin="9"/> |
| 746 | <node ref="U2" pin="10"/> |
| 747 | <node ref="U8" pin="9"/> |
| 748 | </net> |
| 749 | <net code="59" name="7SEG_CLK_T"> |
| 750 | <node ref="U2" pin="12"/> |
| 751 | </net> |
| 752 | <net code="60" name="7SEG_DIO"> |
| 753 | <node ref="U2" pin="14"/> |
| 754 | <node ref="P8" pin="43"/> |
| 755 | </net> |
| 756 | <net code="61" name="7SEG_DIO_T"> |
| 757 | <node ref="U2" pin="15"/> |
| 758 | </net> |
| 759 | <net code="62" name="SR1_CLK"> |
| 760 | <node ref="U2" pin="3"/> |
| 761 | <node ref="P8" pin="11"/> |
| 762 | </net> |
| 763 | <net code="63" name="SR1_CLKINH_T"> |
| 764 | <node ref="U2" pin="4"/> |
| 765 | <node ref="U4" pin="6"/> |
| 766 | <node ref="U6" pin="6"/> |
| 767 | <node ref="U7" pin="6"/> |
| 768 | <node ref="U3" pin="6"/> |
| 769 | <node ref="U5" pin="6"/> |
| 770 | <node ref="U8" pin="6"/> |
| 771 | </net> |
| 772 | <net code="64" name="SR1_CLKINH"> |
| 773 | <node ref="P8" pin="5"/> |
| 774 | <node ref="U2" pin="5"/> |
| 775 | </net> |
| 776 | <net code="65" name="SR1_SHLD_T"> |
| 777 | <node ref="U7" pin="15"/> |
| 778 | <node ref="U6" pin="15"/> |
| 779 | <node ref="U2" pin="6"/> |
| 780 | <node ref="U5" pin="15"/> |
| 781 | <node ref="U3" pin="15"/> |
| 782 | <node ref="U8" pin="15"/> |
| 783 | <node ref="U4" pin="15"/> |
| 784 | </net> |
| 785 | <net code="66" name="SR1_SHLD"> |
| 786 | <node ref="U2" pin="7"/> |
| 787 | <node ref="P8" pin="15"/> |
| 788 | </net> |
| 789 | <net code="67" name="SR1_CLR"> |
| 790 | <node ref="U2" pin="9"/> |
| 791 | <node ref="P8" pin="17"/> |
| 792 | </net> |
| 793 | <net code="68" name="SR4_QH"> |
| 794 | <node ref="U1" pin="9"/> |
| 795 | <node ref="U6" pin="13"/> |
| 796 | </net> |
| 797 | <net code="69" name="SR2_QH__T"> |
| 798 | <node ref="U1" pin="4"/> |
| 799 | </net> |
| 800 | <net code="70" name="SR3_QH_T"> |
| 801 | <node ref="P8" pin="12"/> |
| 802 | <node ref="U1" pin="6"/> |
| 803 | </net> |
| 804 | <net code="71" name="Net-(P8-Pad19)"> |
| 805 | <node ref="P8" pin="19"/> |
| 806 | </net> |
| 807 | <net code="72" name="GNDA_ADC"> |
| 808 | <node ref="P9" pin="34"/> |
| 809 | </net> |
| 810 | <net code="73" name="SYS_RESETN"> |
| 811 | <node ref="P9" pin="10"/> |
| 812 | </net> |
| 813 | <net code="74" name="Net-(P8-Pad1)"> |
| 814 | <node ref="P8" pin="1"/> |
| 815 | </net> |
| 816 | <net code="75" name="Net-(P8-Pad10)"> |
| 817 | <node ref="P8" pin="10"/> |
| 818 | </net> |
| 819 | <net code="76" name="Net-(P8-Pad13)"> |
| 820 | <node ref="P8" pin="13"/> |
| 821 | </net> |
| 822 | <net code="77" name="Net-(P8-Pad2)"> |
| 823 | <node ref="P8" pin="2"/> |
| 824 | </net> |
| 825 | <net code="78" name="Net-(P8-Pad20)"> |
| 826 | <node ref="P8" pin="20"/> |
| 827 | </net> |
| 828 | <net code="79" name="Net-(P8-Pad21)"> |
| 829 | <node ref="P8" pin="21"/> |
| 830 | </net> |
| 831 | <net code="80" name="Net-(P8-Pad22)"> |
| 832 | <node ref="P8" pin="22"/> |
| 833 | </net> |
| 834 | <net code="81" name="Net-(P8-Pad23)"> |
| 835 | <node ref="P8" pin="23"/> |
| 836 | </net> |
| 837 | <net code="82" name="Net-(P8-Pad24)"> |
| 838 | <node ref="P8" pin="24"/> |
| 839 | </net> |
| 840 | <net code="83" name="Net-(P8-Pad25)"> |
| 841 | <node ref="P8" pin="25"/> |
| 842 | </net> |
| 843 | <net code="84" name="Net-(P8-Pad26)"> |
| 844 | <node ref="P8" pin="26"/> |
| 845 | </net> |
| 846 | <net code="85" name="Net-(P8-Pad27)"> |
| 847 | <node ref="P8" pin="27"/> |
| 848 | </net> |
| 849 | <net code="86" name="Net-(P8-Pad28)"> |
| 850 | <node ref="P8" pin="28"/> |
| 851 | </net> |
| 852 | <net code="87" name="Net-(P8-Pad29)"> |
| 853 | <node ref="P8" pin="29"/> |
| 854 | </net> |
| 855 | <net code="88" name="Net-(P8-Pad3)"> |
| 856 | <node ref="P8" pin="3"/> |
| 857 | </net> |
| 858 | <net code="89" name="Net-(P8-Pad30)"> |
| 859 | <node ref="P8" pin="30"/> |
| 860 | </net> |
| 861 | <net code="90" name="Net-(P8-Pad31)"> |
| 862 | <node ref="P8" pin="31"/> |
| 863 | </net> |
| 864 | <net code="91" name="Net-(P8-Pad32)"> |
| 865 | <node ref="P8" pin="32"/> |
| 866 | </net> |
| 867 | <net code="92" name="+3V3"> |
| 868 | <node ref="P9" pin="3"/> |
| 869 | <node ref="P9" pin="4"/> |
| 870 | </net> |
| 871 | <net code="93" name="Net-(P8-Pad33)"> |
| 872 | <node ref="P8" pin="33"/> |
| 873 | </net> |
| 874 | <net code="94" name="VDD_ADC"> |
| 875 | <node ref="P9" pin="32"/> |
| 876 | </net> |
| 877 | <net code="95" name="SR1_CLK_T"> |
| 878 | <node ref="U8" pin="7"/> |
| 879 | <node ref="U6" pin="7"/> |
| 880 | <node ref="U7" pin="7"/> |
| 881 | <node ref="U3" pin="7"/> |
| 882 | <node ref="U2" pin="2"/> |
| 883 | <node ref="U4" pin="7"/> |
| 884 | <node ref="U5" pin="7"/> |
| 885 | </net> |
| 886 | <net code="96" name="SR4_QH_T"> |
| 887 | <node ref="U1" pin="10"/> |
| 888 | <node ref="P8" pin="14"/> |
| 889 | </net> |
| 890 | <net code="97" name="SR5_QH"> |
| 891 | <node ref="U1" pin="11"/> |
| 892 | <node ref="U5" pin="13"/> |
| 893 | </net> |
| 894 | <net code="98" name="SR5_QH_T"> |
| 895 | <node ref="P8" pin="16"/> |
| 896 | <node ref="U1" pin="12"/> |
| 897 | </net> |
| 898 | <net code="99" name="SR2_QH_T"> |
| 899 | <node ref="P8" pin="6"/> |
| 900 | </net> |
| 901 | <net code="100" name="Net-(P8-Pad34)"> |
| 902 | <node ref="P8" pin="34"/> |
| 903 | </net> |
| 904 | <net code="101" name="Net-(P8-Pad35)"> |
| 905 | <node ref="P8" pin="35"/> |
| 906 | </net> |
| 907 | <net code="102" name="Net-(P8-Pad36)"> |
| 908 | <node ref="P8" pin="36"/> |
| 909 | </net> |
| 910 | <net code="103" name="Net-(P8-Pad37)"> |
| 911 | <node ref="P8" pin="37"/> |
| 912 | </net> |
| 913 | <net code="104" name="Net-(P8-Pad38)"> |
| 914 | <node ref="P8" pin="38"/> |
| 915 | </net> |
| 916 | <net code="105" name="Net-(P8-Pad39)"> |
| 917 | <node ref="P8" pin="39"/> |
| 918 | </net> |
| 919 | <net code="106" name="Net-(P8-Pad40)"> |
| 920 | <node ref="P8" pin="40"/> |
| 921 | </net> |
| 922 | <net code="107" name="Net-(P8-Pad41)"> |
| 923 | <node ref="P8" pin="41"/> |
| 924 | </net> |
| 925 | <net code="108" name="Net-(P8-Pad42)"> |
| 926 | <node ref="P8" pin="42"/> |
| 927 | </net> |
| 928 | <net code="109" name="Net-(P8-Pad44)"> |
| 929 | <node ref="P8" pin="44"/> |
| 930 | </net> |
| 931 | <net code="110" name="Net-(P8-Pad46)"> |
| 932 | <node ref="P8" pin="46"/> |
| 933 | </net> |
| 934 | <net code="111" name="Net-(P8-Pad7)"> |
| 935 | <node ref="P8" pin="7"/> |
| 936 | </net> |
| 937 | <net code="112" name="Net-(P8-Pad8)"> |
| 938 | <node ref="P8" pin="8"/> |
| 939 | </net> |
| 940 | <net code="113" name="Net-(P8-Pad9)"> |
| 941 | <node ref="P8" pin="9"/> |
| 942 | </net> |
| 943 | <net code="114" name="SR6_QH"> |
| 944 | <node ref="U1" pin="14"/> |
| 945 | <node ref="U4" pin="13"/> |
| 946 | </net> |
| 947 | <net code="115" name="7SEG_CLK"> |
| 948 | <node ref="P8" pin="45"/> |
| 949 | <node ref="U2" pin="11"/> |
| 950 | </net> |
| 951 | <net code="116" name="e6r"> |
| 952 | <node ref="J5" pin="3"/> |
| 953 | <node ref="RN4" pin="7"/> |
| 954 | <node ref="U3" pin="4"/> |
| 955 | </net> |
| 956 | <net code="117" name="e7r"> |
| 957 | <node ref="RN4" pin="8"/> |
| 958 | <node ref="U3" pin="3"/> |
| 959 | <node ref="J5" pin="2"/> |
| 960 | </net> |
| 961 | <net code="118" name="e8r"> |
| 962 | <node ref="RN4" pin="9"/> |
| 963 | <node ref="J5" pin="1"/> |
| 964 | <node ref="U3" pin="2"/> |
| 965 | </net> |
| 966 | <net code="119" name="f1r"> |
| 967 | <node ref="U8" pin="14"/> |
| 968 | <node ref="RN6" pin="2"/> |
| 969 | <node ref="J6" pin="8"/> |
| 970 | </net> |
| 971 | <net code="120" name="f2r"> |
| 972 | <node ref="RN6" pin="3"/> |
| 973 | <node ref="U8" pin="12"/> |
| 974 | <node ref="J6" pin="7"/> |
| 975 | </net> |
| 976 | <net code="121" name="f3r"> |
| 977 | <node ref="RN6" pin="4"/> |
| 978 | <node ref="J6" pin="6"/> |
| 979 | <node ref="U8" pin="11"/> |
| 980 | </net> |
| 981 | <net code="122" name="f4r"> |
| 982 | <node ref="U8" pin="10"/> |
| 983 | <node ref="RN6" pin="5"/> |
| 984 | <node ref="J6" pin="5"/> |
| 985 | </net> |
| 986 | <net code="123" name="f5r"> |
| 987 | <node ref="U8" pin="5"/> |
| 988 | <node ref="RN6" pin="6"/> |
| 989 | <node ref="J6" pin="4"/> |
| 990 | </net> |
| 991 | <net code="124" name="f6r"> |
| 992 | <node ref="J6" pin="3"/> |
| 993 | <node ref="RN6" pin="7"/> |
| 994 | <node ref="U8" pin="4"/> |
| 995 | </net> |
| 996 | <net code="125" name="f7r"> |
| 997 | <node ref="U8" pin="3"/> |
| 998 | <node ref="J6" pin="2"/> |
| 999 | <node ref="RN6" pin="8"/> |
| 1000 | </net> |
| 1001 | <net code="126" name="f8r"> |
| 1002 | <node ref="U8" pin="2"/> |
| 1003 | <node ref="RN6" pin="9"/> |
| 1004 | <node ref="J6" pin="1"/> |
| 1005 | </net> |
| 1006 | <net code="127" name="e4r"> |
| 1007 | <node ref="RN4" pin="5"/> |
| 1008 | <node ref="U3" pin="10"/> |
| 1009 | <node ref="J5" pin="5"/> |
| 1010 | </net> |
| 1011 | <net code="128" name="e5r"> |
| 1012 | <node ref="U3" pin="5"/> |
| 1013 | <node ref="RN4" pin="6"/> |
| 1014 | <node ref="J5" pin="4"/> |
| 1015 | </net> |
| 1016 | <net code="129" name="e3r"> |
| 1017 | <node ref="U3" pin="11"/> |
| 1018 | <node ref="RN4" pin="4"/> |
| 1019 | <node ref="J5" pin="6"/> |
| 1020 | </net> |
| 1021 | <net code="130" name="c4r"> |
| 1022 | <node ref="J3" pin="5"/> |
| 1023 | <node ref="RN5" pin="5"/> |
| 1024 | <node ref="U6" pin="10"/> |
| 1025 | </net> |
| 1026 | <net code="131" name="b1r"> |
| 1027 | <node ref="U5" pin="14"/> |
| 1028 | <node ref="J2" pin="8"/> |
| 1029 | <node ref="RN3" pin="2"/> |
| 1030 | </net> |
| 1031 | <net code="132" name="b2r"> |
| 1032 | <node ref="U5" pin="12"/> |
| 1033 | <node ref="RN3" pin="3"/> |
| 1034 | <node ref="J2" pin="7"/> |
| 1035 | </net> |
| 1036 | <net code="133" name="b3r"> |
| 1037 | <node ref="RN3" pin="4"/> |
| 1038 | <node ref="U5" pin="11"/> |
| 1039 | <node ref="J2" pin="6"/> |
| 1040 | </net> |
| 1041 | <net code="134" name="b4r"> |
| 1042 | <node ref="U5" pin="10"/> |
| 1043 | <node ref="J2" pin="5"/> |
| 1044 | <node ref="RN3" pin="5"/> |
| 1045 | </net> |
| 1046 | <net code="135" name="b5r"> |
| 1047 | <node ref="RN3" pin="6"/> |
| 1048 | <node ref="U5" pin="5"/> |
| 1049 | <node ref="J2" pin="4"/> |
| 1050 | </net> |
| 1051 | <net code="136" name="b6r"> |
| 1052 | <node ref="RN3" pin="7"/> |
| 1053 | <node ref="U5" pin="4"/> |
| 1054 | <node ref="J2" pin="3"/> |
| 1055 | </net> |
| 1056 | <net code="137" name="b7r"> |
| 1057 | <node ref="U5" pin="3"/> |
| 1058 | <node ref="J2" pin="2"/> |
| 1059 | <node ref="RN3" pin="8"/> |
| 1060 | </net> |
| 1061 | <net code="138" name="b8r"> |
| 1062 | <node ref="U5" pin="2"/> |
| 1063 | <node ref="RN3" pin="9"/> |
| 1064 | <node ref="J2" pin="1"/> |
| 1065 | </net> |
| 1066 | <net code="139" name="c1r"> |
| 1067 | <node ref="J3" pin="8"/> |
| 1068 | <node ref="RN5" pin="2"/> |
| 1069 | <node ref="U6" pin="14"/> |
| 1070 | </net> |
| 1071 | <net code="140" name="c2r"> |
| 1072 | <node ref="RN5" pin="3"/> |
| 1073 | <node ref="U6" pin="12"/> |
| 1074 | <node ref="J3" pin="7"/> |
| 1075 | </net> |
| 1076 | <net code="141" name="c3r"> |
| 1077 | <node ref="RN5" pin="4"/> |
| 1078 | <node ref="J3" pin="6"/> |
| 1079 | <node ref="U6" pin="11"/> |
| 1080 | </net> |
| 1081 | <net code="142" name="c5r"> |
| 1082 | <node ref="RN5" pin="6"/> |
| 1083 | <node ref="J3" pin="4"/> |
| 1084 | <node ref="U6" pin="5"/> |
| 1085 | </net> |
| 1086 | <net code="143" name="c6r"> |
| 1087 | <node ref="RN5" pin="7"/> |
| 1088 | <node ref="J3" pin="3"/> |
| 1089 | <node ref="U6" pin="4"/> |
| 1090 | </net> |
| 1091 | <net code="144" name="c7r"> |
| 1092 | <node ref="RN5" pin="8"/> |
| 1093 | <node ref="J3" pin="2"/> |
| 1094 | <node ref="U6" pin="3"/> |
| 1095 | </net> |
| 1096 | <net code="145" name="c8r"> |
| 1097 | <node ref="RN5" pin="9"/> |
| 1098 | <node ref="U6" pin="2"/> |
| 1099 | <node ref="J3" pin="1"/> |
| 1100 | </net> |
| 1101 | <net code="146" name="d1r"> |
| 1102 | <node ref="U7" pin="14"/> |
| 1103 | <node ref="J4" pin="8"/> |
| 1104 | <node ref="RN2" pin="2"/> |
| 1105 | </net> |
| 1106 | <net code="147" name="d2r"> |
| 1107 | <node ref="J4" pin="7"/> |
| 1108 | <node ref="U7" pin="12"/> |
| 1109 | <node ref="RN2" pin="3"/> |
| 1110 | </net> |
| 1111 | <net code="148" name="d3r"> |
| 1112 | <node ref="U7" pin="11"/> |
| 1113 | <node ref="J4" pin="6"/> |
| 1114 | <node ref="RN2" pin="4"/> |
| 1115 | </net> |
| 1116 | <net code="149" name="d4r"> |
| 1117 | <node ref="RN2" pin="5"/> |
| 1118 | <node ref="U7" pin="10"/> |
| 1119 | <node ref="J4" pin="5"/> |
| 1120 | </net> |
| 1121 | <net code="150" name="d5r"> |
| 1122 | <node ref="RN2" pin="6"/> |
| 1123 | <node ref="J4" pin="4"/> |
| 1124 | <node ref="U7" pin="5"/> |
| 1125 | </net> |
| 1126 | <net code="151" name="d6r"> |
| 1127 | <node ref="RN2" pin="7"/> |
| 1128 | <node ref="J4" pin="3"/> |
| 1129 | <node ref="U7" pin="4"/> |
| 1130 | </net> |
| 1131 | <net code="152" name="d7r"> |
| 1132 | <node ref="RN2" pin="8"/> |
| 1133 | <node ref="U7" pin="3"/> |
| 1134 | <node ref="J4" pin="2"/> |
| 1135 | </net> |
| 1136 | <net code="153" name="d8r"> |
| 1137 | <node ref="U7" pin="2"/> |
| 1138 | <node ref="RN2" pin="9"/> |
| 1139 | <node ref="J4" pin="1"/> |
| 1140 | </net> |
| 1141 | <net code="154" name="e1r"> |
| 1142 | <node ref="RN4" pin="2"/> |
| 1143 | <node ref="U3" pin="14"/> |
| 1144 | <node ref="J5" pin="8"/> |
| 1145 | </net> |
| 1146 | <net code="155" name="e2r"> |
| 1147 | <node ref="U3" pin="12"/> |
| 1148 | <node ref="RN4" pin="3"/> |
| 1149 | <node ref="J5" pin="7"/> |
| 1150 | </net> |
| 1151 | </nets> |
| 1152 | </export> |